Availability: | |
---|---|
| |
Winch | |||||
Lift height | 1-4m, can customized | ||||
Max hanging weight | ≤2.3KG | ||||
Speed | ≤1.2m/s | ||||
Control Model | DMX512、ArtNet | ||||
Channel | 6CH | ||||
Connectors | 3 pin / 5 pin XLR connector in and out | ||||
Screen | 4 Digital tube display | ||||
Traction Cable | ∅3.5MM | ||||
Voltage | AC90V-240V/50-60HZ | ||||
Power | ≤36W | ||||
IP Rating | IP20 Not waterproof | ||||
Environment temputure | - 10℃~50℃ | ||||
Fall protection | Physical braking, Electronic protection | ||||
Installation | Vertical lifting | ||||
Size of winch | 164mm*128mm*261mm | ||||
Weight of winch | 3.65Kg | ||||
Package | Carton(1 in 4)or Flight case(1 in 16) | ||||
Certification | CE/FCC/RoHs | ||||
Light Source | |||||
Output Color | R/G/B | ||||
Ball material | PE | ||||
Size of ball | ∅150mm/∅200mm/ ∅250mm/∅300mm | ||||
Size of tube | Q3D100/Q3D150/Q5D100/Q5D150 | ||||
Standard Accessories | |||||
DMX Signal Cable | 2*0.5㎡*1.5M*1pcs | ||||
Power Cable | 3*1.25㎡*1.5M*1pcs | ||||
Safety Cable | 3mm*600mm*1pcs | ||||
Aluminum hook | 20mm*150mm*1pcs |
Winch | |||||
Lift height | 1-4m, can customized | ||||
Max hanging weight | ≤2.3KG | ||||
Speed | ≤1.2m/s | ||||
Control Model | DMX512、ArtNet | ||||
Channel | 6CH | ||||
Connectors | 3 pin / 5 pin XLR connector in and out | ||||
Screen | 4 Digital tube display | ||||
Traction Cable | ∅3.5MM | ||||
Voltage | AC90V-240V/50-60HZ | ||||
Power | ≤36W | ||||
IP Rating | IP20 Not waterproof | ||||
Environment temputure | - 10℃~50℃ | ||||
Fall protection | Physical braking, Electronic protection | ||||
Installation | Vertical lifting | ||||
Size of winch | 164mm*128mm*261mm | ||||
Weight of winch | 3.65Kg | ||||
Package | Carton(1 in 4)or Flight case(1 in 16) | ||||
Certification | CE/FCC/RoHs | ||||
Light Source | |||||
Output Color | R/G/B | ||||
Ball material | PE | ||||
Size of ball | ∅150mm/∅200mm/ ∅250mm/∅300mm | ||||
Size of tube | Q3D100/Q3D150/Q5D100/Q5D150 | ||||
Standard Accessories | |||||
DMX Signal Cable | 2*0.5㎡*1.5M*1pcs | ||||
Power Cable | 3*1.25㎡*1.5M*1pcs | ||||
Safety Cable | 3mm*600mm*1pcs | ||||
Aluminum hook | 20mm*150mm*1pcs |
Multifunctional Lift Instruction Manual
Suitable for LT-805H、LT(QL)-816M、LT-926Pro
(Version: SF201811)
Important Information:Before the machine is powered on , please be sure to vertically lift and fix it . And make sure that the end of the cable is loaded !
Fixing Method:Vertical lifting
Power supply and Signal connection :
Input Power : 90-220V Stand-alone peak power 75W Each series can be connected in 30 units .
DMX Control line : The "1" core is a braided shielded cable , each series can be connected in 30 units .
Control and Programming :
A. Lighting dedicated console , can direct connection
(MA/Pearl2010/Tiger Touch)
The connection diagram is as below :
B. Computer Software control
Recommend use :
The connection diagram is as below :
Basic Function :
MODE UP DOWN ENTER
Instructions: Press 『UP』 or 『DOWN』 to modify the value . Press 『ENTER』 to confirm and save .
Channel Description :
h001(Total 5 channel)
No. | Function | Description |
1st Channel | Lifting (Position) | 0→255: down; 255←0: up |
2nd Channel | Speed | 0→254: Speed(from fast to slow), 255: brake(pause) |
3rd Channel | R (Red) | R dimming,from dark to bright |
4th Channel | G (Green) | G dimming , from dark to bright |
5th Channel | B (Blue) | B dimming , from dark to bright |
Use Stroke setting :
In any function mode , press and hold the 『MODE』 + 『UP』 button at the same time to enter the use stroke selection menu , select the code corresponding to the stroke . Press 『ENTER』to confirm the save , and automatically return to the function mode after 3 seconds . | ||
No. | Display Code | Description |
1 | L010 | Use the length 1 meter |
2 | L020 | Use the length 2 meters |
3 | L030 | Use the length 3 meters |
And so on ...... |
Brake switch delay time :
Delay time:When the motor is not operating , the waiting time for the brake switch to automatically lock .
In any function mode , at the same times , press 『UP』 + 『ENTER』 , enter the brake switch delay time selection mode . Press 『UP』 or 『DOWN』 to scroll the code . The code “ T001” means the delay time is 1 minute , and the code “T002” delay times is 10 minutes , the “T003” indicates no delay time , and the brake switch is open .
●This manual is only suitable for this model products , if any update without notice .
Multifunctional Lift Instruction Manual
Suitable for LT-805H、LT(QL)-816M、LT-926Pro
(Version: SF201811)
Important Information:Before the machine is powered on , please be sure to vertically lift and fix it . And make sure that the end of the cable is loaded !
Fixing Method:Vertical lifting
Power supply and Signal connection :
Input Power : 90-220V Stand-alone peak power 75W Each series can be connected in 30 units .
DMX Control line : The "1" core is a braided shielded cable , each series can be connected in 30 units .
Control and Programming :
A. Lighting dedicated console , can direct connection
(MA/Pearl2010/Tiger Touch)
The connection diagram is as below :
B. Computer Software control
Recommend use :
The connection diagram is as below :
Basic Function :
MODE UP DOWN ENTER
Instructions: Press 『UP』 or 『DOWN』 to modify the value . Press 『ENTER』 to confirm and save .
Channel Description :
h001(Total 5 channel)
No. | Function | Description |
1st Channel | Lifting (Position) | 0→255: down; 255←0: up |
2nd Channel | Speed | 0→254: Speed(from fast to slow), 255: brake(pause) |
3rd Channel | R (Red) | R dimming,from dark to bright |
4th Channel | G (Green) | G dimming , from dark to bright |
5th Channel | B (Blue) | B dimming , from dark to bright |
Use Stroke setting :
In any function mode , press and hold the 『MODE』 + 『UP』 button at the same time to enter the use stroke selection menu , select the code corresponding to the stroke . Press 『ENTER』to confirm the save , and automatically return to the function mode after 3 seconds . | ||
No. | Display Code | Description |
1 | L010 | Use the length 1 meter |
2 | L020 | Use the length 2 meters |
3 | L030 | Use the length 3 meters |
And so on ...... |
Brake switch delay time :
Delay time:When the motor is not operating , the waiting time for the brake switch to automatically lock .
In any function mode , at the same times , press 『UP』 + 『ENTER』 , enter the brake switch delay time selection mode . Press 『UP』 or 『DOWN』 to scroll the code . The code “ T001” means the delay time is 1 minute , and the code “T002” delay times is 10 minutes , the “T003” indicates no delay time , and the brake switch is open .
●This manual is only suitable for this model products , if any update without notice .